Products and services
for energy savings and comfort
at home and in commercial & industrial buildings

DN 10, DN 15, DN 20, DN 25

DN 10, DN 15, DN 20, DN 25
References
6301033 DN 10 RT 2012
6301034 DN 15 RT 2012
6301035 DN 20 RT 2012
6301036 DN 25 RT 2012 (φ extérieur de la canalisation = 26 mm)

TYWATT 5200 or TYWATT 5300 flow and temperature sensors

Others documents

< Close >
• Essential for taking energy consumption readings for the heater and DHW system
• Silent sensor
• Highly accurate flow and temperature readings
  • Low load loss
• Integrated temperature reading
• High wear resistance
• Maintenance-free

 

• Measures the flow rate of a fluid by vortex effect and reads the fluid temperature directly in the duct
• Connection to TYWATT 5200 thermal integrator or TYWATT 5300 flowmeter transmitter

DN 10  - Piping inside 10 mm | Piping outside 12 mm

  DN 15 Piping inside 14 mm | Piping outside16 mm
DN 20 Piping inside 20 mm| Piping outside 22 mm
DN 25 Piping inside 26 mm | Piping outside 28 mm

 

• Fluid temperature measurement range: +5 to +125°C
• Ambient operating temperature: +5 to + 85°C
• Maximum pressure: 12 bar at + 40°C or 6 bar at 100°C
• Horizontal or vertical installation with threaded unions (not included)
• O-ring included
• Visual indication of the direction of flow
  • Drinking water certification KTW, W270, WRAS
• DN sensor powered by TYWATT 5200 or TYWATT 5300
• Cable length with connector: 2 m (IP 65) (do not extend)
• Female connector M12x1 / 5 poles (IP 65)
• Material: polyamide PAT6T
• Contents: 1 sensor + 1 connector cable

 

Schéma
EN